Skip to content
ICD-10 Atlas home

Worked example: total knee replacement in ICD-10-PCS (0SRC0J9, 0SRD0J9)

Coding a total knee arthroplasty in ICD-10-PCS: the Replacement root operation, right versus left knee joint, the synthetic substitute device values, cemented versus uncemented, and how partial and bilateral replacements differ.

Last updated

In plain English

A total knee replacement is coded to the root operation Replacement in the Lower Joints body system, table 0SR. For a cemented total replacement of the right knee with a synthetic prosthesis, the code is 0SRC0J9, Replacement of Right Knee Joint with Synthetic Substitute, Cemented, Open Approach.

Three characters carry most of the decisions: the body part (which knee, and whether the whole joint or one surface), the device (which kind of synthetic substitute), and the qualifier (cemented, uncemented or not specified). The approach for knee replacement in this table is always Open.

Knee replacement choices in table 0SR

DocumentationCharacterValue
Right knee, whole joint4 Body PartC Knee Joint, Right
Left knee, whole joint4 Body PartD Knee Joint, Left
Only the femoral or tibial surface replaced4 Body PartT/U Femoral Surface or V/W Tibial Surface
Standard total knee prosthesis6 DeviceJ Synthetic Substitute
Oxidized zirconium on polyethylene prosthesis6 Device6 Synthetic Substitute, Oxidized Zirconium on Polyethylene
Medial or lateral unicondylar prosthesis6 DeviceL or M (unicondylar), N for patellofemoral
Components cemented / uncemented / not documented7 Qualifier9 Cemented, A Uncemented, Z No Qualifier

Codes in this guide

Official titles and character meanings come straight from the code files. The explanations around them are ours.

Official descriptor · CMS ICD-10-PCS

0SRC0J9Replacement of Right Knee Joint with Synthetic Substitute, Cemented, Open Approach

Code anatomy: what each character means
  1. 0Section (character 1): Medical and Surgical
  2. SBody System (character 2): Lower Joints
  3. ROperation (character 3): Replacement
  4. CBody Part (character 4): Knee Joint, Right
  5. 0Approach (character 5): Open
  6. JDevice (character 6): Synthetic Substitute
  7. 9Qualifier (character 7): Cemented

PCS table 0SR

Official descriptor · CMS ICD-10-PCS

0SRD0JAReplacement of Left Knee Joint with Synthetic Substitute, Uncemented, Open Approach

Code anatomy: what each character means
  1. 0Section (character 1): Medical and Surgical
  2. SBody System (character 2): Lower Joints
  3. ROperation (character 3): Replacement
  4. DBody Part (character 4): Knee Joint, Left
  5. 0Approach (character 5): Open
  6. JDevice (character 6): Synthetic Substitute
  7. AQualifier (character 7): Uncemented

PCS table 0SR

Official descriptor · CMS ICD-10-PCS

0SRC0L9Replacement of Right Knee Joint with Medial Unicondylar Synthetic Substitute, Cemented, Open Approach

Code anatomy: what each character means
  1. 0Section (character 1): Medical and Surgical
  2. SBody System (character 2): Lower Joints
  3. ROperation (character 3): Replacement
  4. CBody Part (character 4): Knee Joint, Right
  5. 0Approach (character 5): Open
  6. LDevice (character 6): Synthetic Substitute, Unicondylar Medial
  7. 9Qualifier (character 7): Cemented

PCS table 0SR

Why Replacement

Replacement is defined in the PCS tables as putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part. A knee arthroplasty removes the damaged joint surfaces and puts a prosthesis in their place, which is exactly that definition.

Section B3.1b uses joint replacement as its first example of an integral component: resection of a joint as part of a joint replacement is included in the definition of Replacement and is not coded separately. So the bone cuts that remove the arthritic surfaces are not coded as Excision or Resection.

Body part: whole joint or one surface

Table 0SR has body part values for the whole knee joint (C right, D left) and for its individual surfaces: femoral surface (T right, U left) and tibial surface (V right, W left). A total knee replacement replaces both the femoral and tibial surfaces, and the whole-joint value is the one that describes it.

There is no bilateral value for the knee joint. Section B4.3 uses the knee as its example: the identical procedure performed on both knee joints is coded twice, once with Knee Joint, Right and once with Knee Joint, Left. A bilateral cemented total knee replacement is 0SRC0J9 plus 0SRD0J9.

Device and qualifier

The device character describes what stays in the joint, which is the only kind of device PCS codes (Section B6.1a). The general value J, Synthetic Substitute, fits a standard total knee prosthesis. More specific values exist for an oxidized zirconium on polyethylene prosthesis (6), unicondylar prostheses (L medial, M lateral) and a patellofemoral prosthesis (N); use them when the operative report or implant record supports them.

The qualifier records fixation: 9 for cemented and A for uncemented. Z, No Qualifier, is the choice when the record doesn't say. A cemented left total knee replacement is 0SRD0J9; an uncemented one is 0SRD0JA. A cemented medial unicondylar replacement of the right knee is 0SRC0L9.

Related cases that use other tables

A temporary articulating spacer placed during a staged procedure uses the device value E, Articulating Spacer, in the same table. Taking out an existing prosthesis is the root operation Removal (table 0SP), and putting in a new liner alone is Supplement (table 0SU). Revision surgery often combines more than one of these, and each part is coded with the root operation that matches what was done.

Common mistakes

  • Adding an Excision or Resection code for the bone cuts. They are part of Replacement (Section B3.1b).
  • Coding a bilateral knee replacement once. There is no bilateral knee value, so code each knee (Section B4.3).
  • Choosing Z for the qualifier when the operative report says the components were cemented. Read the implant details before defaulting.
  • Using the whole-joint value for a partial knee replacement that only resurfaces one compartment, or the unicondylar device value for a total knee.

Related codes

  • 0SR Table 0SR: Replacement, Lower Joints

Questions

The femoral component was cemented and the tibial component wasn't. Which qualifier?

The tables only offer Cemented, Uncemented or No Qualifier for the whole joint. Mixed fixation isn't separately described, so follow your facility's coding guidance for hybrid fixation and document the choice.

The surgeon used a small, minimally invasive incision. Does the approach change?

No. In table 0SR the knee joint rows offer only the approach 0, Open, so every knee replacement in this table is coded with the open approach.

Is a computer-assisted or robotic-assisted knee replacement a different code?

No. The Replacement code stays the same. Robotic assistance can be reported with an additional code from table 8E0 when the facility captures it.

More on icd-10-pcs procedure coding

This guide was drafted with AI assistance and checked against the cited official sources before publication. It explains official coding conventions in plain English and is not medical or billing advice. See our editorial policy.

Sources